Documents

2 pages
148 views

Boilers 23

of 2
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Description
boilers catalogo
Transcript
    www.jumag.de Jumag Dampferzeuger GmbH Tel: +49 (0)6201-84603-0 Dimensions Steam boiler DG boiler type DG160 DG260 DG360 DG460 DG560 Charging height A* 1, 130 mm 1, 363 mm 1, 563 mm 1, 563 mm 1, 563 mm Total height B* 1, 460 mm 1, 756 mm 2, 043 mm 2, 043 mm 2, 140 mm Width C 800 mm 800 mm 800 mm 930 mm 930mm Total depth D 1, 380 mm 1, 620 mm 1, 620 mm 1, 750 mm 1, 750mm Depth E (at 90 ° twisted economizer) 1, 350 mm 1, 350 mm 1, 480 mm 1, 480 mm Depth F 1, 080 mm 1, 100mm 1, 100mm 1, 230mm 1, 230mm Height G, leaving blow down 225 mm 275 mm 275 mm 275 mm 275 mm Height H *, exhaust outlet 795 mm 1, 438 mm 1, 438 mm 1, 438 mm 1, 438 mm *) Heights may be reduced upon request up to 100mm. However, then only limited truck transport is possible.    www.jumag.de Jumag Dampferzeuger GmbH Tel: +49 (0)6201-84603-0 Further technical data Steam boiler DG Boiler type DG120 DG160 DG260 DG360 DG460 DG560 Steam up 120 kg / h 2 kg / min 160 kg / h 2.7kg / min 260 kg / h 4.3kg / min 360 kg / h 6 kg / min 460 kg / h 7.7 kg / min 560 kg / h 9.3 kg / min Max. operating pressure 13 barÜ Max. Working pressure 2_11_21 heat load 75 kW 110 kW 175 kW 245kW 315kW 400 kW heat output 70 kW 105 kW 170 kW 235 kW 300 kW 380 kW Total (incl. Eco) 19 Liter 27 Liter 45 Liter 60 Liter 75 Liter 75 Liter low water level 6 liters 7 Liter 10 Liter 12 Liter 15 Liter 15 Liter Heating time in min 5 5 8 8 8 8 max. Oil throughput (11, 8kWh / kg) 6.3 kg/h 9.3 kg/h 14.8 kg/h 20.7 kg/h 26.7kg/h 33.9 kg/h max. Gas additive (10, 35kWh / m³) 7.2 m³ / h 10.6 m³ / h 16.9 m³ / h 23.7 m³ / h 30.4 m³ / h 38.6 m³ / h min. Gas flow pressure (on the burner at 1 'pipe) 14 mbar 16 mbar 22 mbar 20 mbar 24 mbar 27 mbar flue gas mass flow 0.04 kg / s 0.05 kg / s 0.08 kg / s 0.11 kg / s 0.14 kg / s 0.18 kg / s min. Chimney draft 0.2 mbar 0.2 mbar 0.15 mbar 0.15 mbar 0.15 mbar 0.1 mbar Electrical connection 400 V/50Hz 400 V/50Hz 400 V/50Hz 400 V/50Hz 400 V/50Hz 400 V/50Hz Electrical Power requirement 2, 4 kW 2, 4 kW 3, 2 kW 3, 2 kW 4, 0 kW 4, 0 kW min. ambient temperature 5 °C 5 °C 5 °C 5 °C 5 °C 5 °C max. ambient temperature 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C net weight 460 kg 580 kg 700 kg 800 kg 1200 kg 1300 kg Noise level oil gas 58 dbA 61 bdA 58 dbA 61 dbA 62 dbA 66 dbA 73 dbA 73 dbA 73 dbA 73 dbA 76 dbA 76 dbA Terminal flue outlet 150 mm 150 mm 300 mm 300 mm 300 mm 300 mm Gas Connection 1 1 1 1 1 1 Connection steam valve DN20 DN20 DN20 DN20 DN25 DN25 Feed water pump connection 1‘‘  1 1 1 1 1 Safety valve connection DN25 DN25 DN25 DN25 DN32 DN32 blow down connection ¾‘‘   ¾‘‘   ¾‘‘   ¾‘‘   ¾‘‘   ¾‘‘  The data are valid under the following conditions:    Use of an exhaust gas heat exchanger (economiser)    Feed water temperature of 90 ° C    Working pressure of 6 bar overpressure   
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks