Portable Flow Meter for Dirty or Aerated Liquids Troubleshoot Flow from Outside a Pipe Non-Contacting Doppler Flow Meter Greyline PDFM 5.1 Displays, Datalogs Transmits and Totalizes Flow in Closed Pipes Simple 5-key Calibration 300,000 point Data Logger 4-20mA Output 10-Digit Totalizer AC/DC Operation Built-in Rechargeable Battery Fast,
Transcript
  Portable Flow Meter  for Dirty orAerated Liquids TroubleshootFlow froma PipeOutside Non-Contacting DopplerFlow Meter Greyline PDFM 5.1 Displays, DatalogsTransmits andTotalizesFlow in Closed Pipes Simple-key Calibration5300,000 point Data Logger 4-20mAOutput10-DigitTotalizer  AC/DC OperationBuilt-in Rechargeable Battery Versatile, Easy to UseIdeal for Problem Liquids Use a Greyline PDFM 5.1 Portable Doppler Flow Meter to monitor andbalance flow, or to troubleshoot flow problems inpipes. It is ideal tofullevaluate performance of in-line flow meters and can be installed,calibrated and started-up in minutes. Use it for projects where apermanent flowmeter is not required or to temporarily replace installedflow transmitters.The PDFM 5.1 ultrasonic sensor ison the outside of a pipe.Anclampedacoustic pulse is reflected back to the sensor from particles or gases inthe flowing liquid.The flow rate of any fluid can be measured as long as itcontains air bubbles or solids. It is ideal for wastewater, slurries, sludge,and most chemicals, acids, caustics, and lubrication fluids.With its internal battery the PDFM 5.1 can be operated all day and thenrecharged overnight. For continuous use it can be powered by a supplied110-240VAC wall plug adapter.A300,000 point data logger is built-in. Fast, Easy Flow MeasurementUltrasonicwith Non-ContactingSensor   Quick, Easy Flow Measurements from Outside a Pipe Each Greyline PDFM 5.1 comes complete withcarrying case,rugged watertightstrap-on sensor and stainless steel mounting kit.Use the simple 5-key menusystem to select units of measurement and to calibrate to any pipe diameter ½”(12.5 mm) or larger. Simple start-up and Calibration Sensor mounting and a full calibration can be done in just a few minutes. It isfast and easy! Put coupling compound() on the sensor facegelincludedandmounton the outside of a pipe with the stainless steel mountingthe sensor bracket (supplied).fiveUse the-key calibration system to enter pipe diameter and to select your choice of engineering units (gallons, litres etc.)The PDFM 5.1will immediately begin to display, transmit and totalize. No Calculations - No Programming Codes Select your choice of display units: the PDFM 5.1 will display and totalize flow volume in gallons, lites, cubic feet or cubicr meters. If you change from one measurement system to another, the PDFM 5.1 will automatically and instantly calculateand convert the flow display and totalizer.alibrate topipe size using the keypad to enter inside diameter.Cthe Built-in0,000 point Data ogger 30land PC Software Set up the PDFM 5.1's data logger to store time and date-stamped flow values from 1second tominute intervals. Or use05the convenient 'Flow Report' format where total, minimum,maximum and average flow rates are stored in your choice of hourly or daily summaries.Transfer flow logs to your PC or laptopthrough the PDFM 5.1'soutpu . Greyline Logger softwareUSBt(included)displays data in both graph and table formats andexports to graphic or text file formats for use in other programs. “Sleep Mode”for Extended Data Logging onBattery Power  Sleep mode extends battery life for long-term data logging atlocations whereAC power input is not available. Between logging intervals the flowmeter drops into a stand-by mode untila flow reading is requested by the data logger. Flow rates are sampled continuously for 10 seconds and then the PDFM5.1 returns to sleep until the next logger point is required. With 5 minute sample intervals the PDFM can data log for about18 days on battery power. New Signal Processing for reliableAccuracy  The PDFM 5.1 Doppler flow algorithm filters out background noise andinterference.The high speed digital signal processor discriminates againstweak and distorted signals. When the processor cannot measure accuratelythe meter will display zero flow and indicate low signal confidence. Battery Powereda Full Day’s Work for  With its built-inrechargeable battery, you can operate the PDFM 5.1.NiMHup to 18 hours continuously Displaybrightness is adjustable to conserve power.(100-240VACto activate the 4-20mAoutputPlug into anAC outlet50/60Hz)andrecharge fully intohours.You can continue to use the PDFM 5.1 while charging.to68 Solve Flow Problems  Troubleshoot and Balance Flow  Check Performance of Pumps or other Flow Meters DOPPLER SIGNALBACKGROUNDNOISE  General Specifications Flow Rate Range:Pipe Size:Display:Power Input:Outputs:Data Logger:PC Software:Electronics Operating Temperature:Electronics Enclosure:Carry Case:Accuracy:Calibration:Language Selection:Sensitivity:Approvals: Sensor Specifications Standard Model PSE:4Sensor Mounting Kit:Operating Temperature: Options Sensor Cable:Sensor Mounting: PDFM 5.1 Specifications Greyline PDFM 5.1 Portable Doppler Flow Meter  ±1±3in most applications0.to 40 ft/sec (0.0to 12.2 m/sec)Ultrasonic Sensor mounts on any pipe from ½ to 180 ID (12.5 mm to 4.5 m)White, backlit matrix - displays flow rate, totalizer, operating mode and calibration menuBuilt-inbatteryNiMHfor up to 18 hours continuous operationExternalwith24inputcharger100-0VAC 50/60Hz4-20mA(500 ohm)whenAC poweredUSBfor Data Log transfer by direct PC connectionP30rogrammable0,000 data point capacity, time and date stamped or formatted flowreports including total, average, minimum, maximum and times of occurrence‘’s Vista or higher. RGreyline Loggerfor Windowetrieves, displays and saves data log files-10° to 140°F (-23° to 60°C)Portable,ABS enclosureRated IP67 with protective molded foam insert±2% of reading or 0.1 ft/sec (0.03 m/sec). Requires solids or bubbles minimum size of 100microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%Built-in-key programming with user-friendly calibration menu. Password protected.5English, French, Spanish Adjustable, Damping: adjustablecut-off Charger is CE and ULapproved.The PDFM 5.1 is not certified for use in hazardous ratedlocationsClamp-on, single-head ultrasonic for pipes from ½ to 180 ID (12.5 mm to 4.5 m) with12 ft (3.4 m) shielded dual-coaxial cableStainless steel pipe clamp and 5.3 oz. (150 g) silicone coupling compound-40° to°F (-40° to°C)30015050 ft (15 m) sensor cable extension, shielded, with connectorsExtra silicone coupling compound.Additional stainless steel pipe clamps Dimensions ENCLOSUREPSE4 ULTRASONICDOPPLER SENSOR 4.33”110 mm8”204 mm1.6”41 mm12 ft / 3.6 mSIDEVIEW 3.375”/ 85 mm1.375”35 mm1.5”38 mmENDVIEW   Ideal for Tough FlowApplications The PDFM 5.1 works best withdifficult liquidsin“”applications that would damage regular flow meters.Because the sensor is mounted on the outside of thepipe, there is no contact with the moving fluid.Thesensor straps onto the outside of pipe ultrasonics ½(12.5 mm)ID or larger and measures flow in common pipematerials: PVC, carbon steel, stainless steel, cast iron,fiberglass, and lined pipes...any pipe that conducts ultrasound.Doppler signals cannot be transmitted through pipe walls which containair pockets (materials like concrete and wood), or loose insertion liners (withan air gap between the liner and pipe wall). Because the sensor is so easy toinstall you can test any application and pipe material in a few minutes. How it Works The PDFM 5.1 ultrasonic sensor injects highfrequency sound through the pipe wall and intothe flowing liquid. Gas bubbles or solidssuspended in the liquid reflect the ultrasonicsignal back to the sensor. When this soundis reflected from moving bubbles or particlesit is returned to the sensor at an alteredfrequency.This frequency shift is called theDoppler effect.The PDFM 5.1 continuouslymeasures the change from it's transmittedfrequency to the received frequency toaccurately calculate flow. New PDFM 5.1Portable Doppler Flow Meter   No ObstructionNo Pressure Drop  –  Just Minutes to Install and Calibrate Contact a Greyline sales representative in your area or phone one of our salesengineers. Describe your requirements and receive our prompt quotation.Take advantage of Greyline's applications experience. Phone 1-888-473-9546 for advice and information on applications, installation or service for Greyline instruments.The Greyline PDFM 5.1 Portable Doppler Flow Meter must meet your requirements.Discuss your application with a Greyline representative to arrange a performance test.Quality of Materials and Workmanship - Each instrument manufactured by Greyline iswarranted against defects in materials and workmanship for a period of one year fromdate of purchase. Refer to our limited warranty included with each product. How to Order  Applications Support No RiskAppraisal The Greyline Guarantee Recommendedor:f   sewage  treated wastewater   aerated water   sludge and slurries  chemicals and solvents  viscous liquids  abrasives  food products  pulp stock  acids and caustics ThePDFM5.1isidealtomeasurefullpipeflowof anyliquidcontaininggasbubblesorsolidslarger than100micronsandinconcentrationsgreater than75ppm. RELIABLE MEASUREMENT AND CONTROL Canada:16456 Sixsmith Dr., Long Sault, Ont. K0C 1P0 Tel: 613-938-8956 / 888-473-9546Fax: 613-938-4857 USA:105 Water Street, Massena NY13662 Tel: 315-788-9500 / 888-473-9546Fax: 315-764-0419Internet:www.greyline.com E-mail: info@greyline.com SOUND WAVETRANSMITTEDFROM SENSORBUBBLES OR SOLIDSREFLECT SOUNDSOUND WAVESREFLECTEDBACK TO SENSOR SENSOR
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x