Air System Inputs

of 8
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Description
Air System Inputs
Transcript
  07/31/2013  AC/DC Room Input Data   10:35AM 1.General Details:  Air System Name  AC/DC Room Equipment Type Terminal Units  Air System Type Split DX Fan Coil Number of zones 1 Ventilation Direct Ventilation2.Ventilation System Components: (Common Ventilation System not used: no inputs) 3.Zone Components:Space Assignments:Zone 1: AC/DC Room  AC & DC Roomx1 Thermostats and Zone Data:  Zone  All  Cooling T-stat: Occ. 23.6 °C Cooling T-stat: Unocc. 23.6 °C Heating T-stat: Occ. 22.2 °C Heating T-stat: Unocc. 22.2 °C T-stat Throttling Range 0.83 °K Thermostat Schedule Full Time Operation  Unoccupied Cooling is  AvailableCommon Terminal Unit Data:Cooling Coil:  Design Supply Temperature 14.4 °C Coil Bypass Factor 0.100  Cooling Source  Air-Cooled DX  Schedule JFMAMJJASONDHeating Coil:  Design Supply Temperature 35.0 °C Heating Source  Air Source Heat Pump  Schedule JFMAMJJASOND  Fan Control Cycled  Ventilation Sizing Method Sum of Space OA AirflowsTerminal Units Data:  Zone  All  Terminal Type Fan Coil  Minimum Airflow 2.00  ACH Fan Performance 100 Pa Fan Overall Efficiency 50 % 4.Sizing Data (Computer-Generated):System Sizing Data: Cooling Supply Temperature 14.4 °CHeating Supply Temperature 35.0 °C Hydronic Sizing Specifications:  Chilled Water Delta-T 5.6 °K Hot Water Delta-T 11.1 °K Safety Factors:  Cooling Sensible 15 % Cooling Latent 0 % Heating 0 % Zone Sizing Data:  Zone Airflow Sizing Method Sum of space airflow rates  Space Airflow Sizing Method Individual peak space loadsZoneSupply AirflowZone Htg UnitReheat CoilVentilation(L/s)(kW)(kW)(L/s)1 1350.0--9.6Hourly Analysis Program v4.51Page 1 of 8   AC/DC Room Input Data Project Name: LENA Farm 66kV Substation - Control Building07/31/2013 Prepared by: PSP10:35AM 5. Equipment DataTerminal Cooling Units - Air-Cooled DXZoneEstimated Maximum Load (kW)Design OAT (°C)Equipment SizingGross Cooling Capacity (kW)Capacity Oversizing Factor (%)Compressor + OD Fan Power (kW) ARI Performance RatingUnitsConventional Cutoff OAT (°C)1 14.935.0Auto-Sized16.410-3.22EER-17.8 Terminal Heating Units - ASHPZoneEstimated Maximum Load (kW)Design OAT (°C)Equipment SizingGross Heating Capacity (kW)Capacity Oversizing Factor (%)Compressor + OD Fan Power (kW) ARI Performance RatingUnitsCutoff OAT (°C)1 3.58.3Auto-Sized3.810-3.20COP-26.1Hourly Analysis Program v4.51Page 2 of 8  Communication Room Input Data Project Name: LENA Farm 66kV Substation - Control Building07/31/2013 Prepared by: PSP10:35AM 1. General Details:  Air System Name Communication Room  Equipment Type Terminal Units  Air System Type Split DX Fan Coil  Number of zones 1  Ventilation Direct Ventilation2. Ventilation System Components: (Common Ventilation System not used: no inputs) 3. Zone Components:Space Assignments:Zone 1: Communication Room  Communication Roomx1 Thermostats and Zone Data:  Zone  All  Cooling T-stat: Occ. 23.6 °C Cooling T-stat: Unocc. 23.6 °C Heating T-stat: Occ. 22.2 °C Heating T-stat: Unocc. 22.2 °C T-stat Throttling Range 0.83 °K Thermostat Schedule Full Time Operation  Unoccupied Cooling is  AvailableCommon Terminal Unit Data:Cooling Coil:  Design Supply Temperature 14.4 °C Coil Bypass Factor 0.100  Cooling Source  Air-Cooled DX  Schedule JFMAMJJASONDHeating Coil:  Design Supply Temperature 35.0 °C Heating Source  Air Source Heat Pump  Schedule JFMAMJJASOND  Fan Control Cycled  Ventilation Sizing Method Sum of Space OA AirflowsTerminal Units Data:  Zone  All  Terminal Type Fan Coil  Minimum Airflow 2.00  ACH Fan Performance 100 Pa Fan Overall Efficiency 50 % 4. Sizing Data (Computer-Generated):System Sizing Data:  Cooling Supply Temperature 14.4 °C Heating Supply Temperature 35.0 °C Hydronic Sizing Specifications:  Chilled Water Delta-T 5.6 °K Hot Water Delta-T 11.1 °K Safety Factors:  Cooling Sensible 15 % Cooling Latent 0 % Heating 0 % Zone Sizing Data:  Zone Airflow Sizing Method Sum of space airflow rates  Space Airflow Sizing Method Individual peak space loadsZoneSupply AirflowZone Htg UnitReheat CoilVentilation (L/s)(kW)(kW)(L/s)1 789.0--7.5 5. Equipment Data Hourly Analysis Program v4.51Page 3 of 8  Communication Room Input Data Project Name: LENA Farm 66kV Substation - Control Building07/31/2013 Prepared by: PSP10:35AM Terminal Cooling Units - Air-Cooled DXZoneEstimated Maximum Load (kW)Design OAT (°C)Equipment SizingGross Cooling Capacity (kW)Capacity Oversizing Factor (%)Compressor + OD Fan Power (kW) ARI Performance RatingUnitsConventional Cutoff OAT (°C)1 8.635.0Auto-Sized9.510-3.22EER-17.8 Terminal Heating Units - ASHPZoneEstimated Maximum Load (kW)Design OAT (°C)Equipment SizingGross Heating Capacity (kW)Capacity Oversizing Factor (%)Compressor + OD Fan Power (kW) ARI Performance RatingUnitsCutoff OAT (°C)1 3.88.3Auto-Sized4.210-3.20COP-26.1Hourly Analysis Program v4.51Page 4 of 8
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x